<?xml version="1.0" encoding="ISO-8859-1"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	>
<channel>
	<title>Comments on: Cómo utilizar el Watchdog del módem GPRS Siemens TC65</title>
	<atom:link href="http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/</link>
	<description>Blog personal sobre alta tecnología y dispositivos electrónicos avanzados</description>
	<pubDate>Thu, 09 Sep 2010 09:48:54 +0000</pubDate>
	<generator>http://wordpress.org/?v=2.7</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-18814</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Tue, 16 Mar 2010 18:36:48 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-18814</guid>
		<description>Hola Luciano,

si quieres apagar el módulo usa el comando AT^SMSO
Si quieres encender el módem deberás generar un pulso de 400ms en el pin de IGT o usar el comando AT+CALA para generar una alarma que "prenda" el módem al cabo de x segundos.

Salu2.</description>
		<content:encoded><![CDATA[<p>Hola Luciano,</p>
<p>si quieres apagar el módulo usa el comando AT^SMSO<br />
Si quieres encender el módem deberás generar un pulso de 400ms en el pin de IGT o usar el comando AT+CALA para generar una alarma que &#8220;prenda&#8221; el módem al cabo de x segundos.</p>
<p>Salu2.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Luciano</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-18810</link>
		<dc:creator>Luciano</dc:creator>
		<pubDate>Tue, 16 Mar 2010 14:48:34 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-18810</guid>
		<description>Buen dia queria hacer una consulta sobre el TC65, la verdad no sabia bien donde postearla, porque no es relativa al watchdog, pero es lo mas similar que encontre.

MI CONSULTA ES LA SIGUIENTE:

Hay alguna forma de prender y apagar el modem? ya sea por software, o por SMS?

no hable de reiniciar, sino de Apagar y Prender.

gracias! saludos!</description>
		<content:encoded><![CDATA[<p>Buen dia queria hacer una consulta sobre el TC65, la verdad no sabia bien donde postearla, porque no es relativa al watchdog, pero es lo mas similar que encontre.</p>
<p>MI CONSULTA ES LA SIGUIENTE:</p>
<p>Hay alguna forma de prender y apagar el modem? ya sea por software, o por SMS?</p>
<p>no hable de reiniciar, sino de Apagar y Prender.</p>
<p>gracias! saludos!</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7769</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Thu, 19 Mar 2009 19:29:55 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7769</guid>
		<description>Hola Ulises,

dices que te ocurre muy aleatóricamente. ¿Has probado con otro operador? ¿has comprobado la cobertura con AT+CSQ? ¿Has comprobado si estás registrado con AT+COPS? ¿has comprobado cuanta memoria ram y flash te queda disponible?

Salu2</description>
		<content:encoded><![CDATA[<p>Hola Ulises,</p>
<p>dices que te ocurre muy aleatóricamente. ¿Has probado con otro operador? ¿has comprobado la cobertura con AT+CSQ? ¿Has comprobado si estás registrado con AT+COPS? ¿has comprobado cuanta memoria ram y flash te queda disponible?</p>
<p>Salu2</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ulises</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7713</link>
		<dc:creator>Ulises</dc:creator>
		<pubDate>Mon, 16 Mar 2009 20:01:54 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7713</guid>
		<description>Gracias Blog por toda tu ayuda, me esta sirviendo mucho.
Te comento que me esta ocurriendo algo extraño en mi aplicacion, muy aleatoriamente me esta lanzando lo siguiente:
[Application Finished]

^SIS: 1, 0, 13, "The network is unavailable"
^SISW: 1, 2
^SHUTDOWN

Yo al comiezo de mi aplicacion, abro un socket , envio y escribo datos en el, para ello utilizo los comandos AT para configurar el Service Profile y el Conection Profile. No se cual puede ser la causa de este error.
Muchas Gracias!
Saludos</description>
		<content:encoded><![CDATA[<p>Gracias Blog por toda tu ayuda, me esta sirviendo mucho.<br />
Te comento que me esta ocurriendo algo extraño en mi aplicacion, muy aleatoriamente me esta lanzando lo siguiente:<br />
[Application Finished]</p>
<p>^SIS: 1, 0, 13, &#8220;The network is unavailable&#8221;<br />
^SISW: 1, 2<br />
^SHUTDOWN</p>
<p>Yo al comiezo de mi aplicacion, abro un socket , envio y escribo datos en el, para ello utilizo los comandos AT para configurar el Service Profile y el Conection Profile. No se cual puede ser la causa de este error.<br />
Muchas Gracias!<br />
Saludos</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Pua</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7644</link>
		<dc:creator>Pua</dc:creator>
		<pubDate>Tue, 10 Mar 2009 08:56:03 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7644</guid>
		<description>hola,

Desde Java el USB solo puede ser usado como sytemout, no es un puerto bidirecional.

Salu2

Pua</description>
		<content:encoded><![CDATA[<p>hola,</p>
<p>Desde Java el USB solo puede ser usado como sytemout, no es un puerto bidirecional.</p>
<p>Salu2</p>
<p>Pua</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ulises</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7633</link>
		<dc:creator>Ulises</dc:creator>
		<pubDate>Mon, 09 Mar 2009 18:24:31 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7633</guid>
		<description>Muchas Gracias por tu ayuda!!
Otra de mis dudas es si, una vez corriendo mi aplicacion, puedo enviar datos por el puerto USB y la aplicacion que este escuchando en ese puerto? como si utilizara un tx y un rx de un puerto serie? De ser asi, como tendria que configurarlo desde java? 

Saludos.</description>
		<content:encoded><![CDATA[<p>Muchas Gracias por tu ayuda!!<br />
Otra de mis dudas es si, una vez corriendo mi aplicacion, puedo enviar datos por el puerto USB y la aplicacion que este escuchando en ese puerto? como si utilizara un tx y un rx de un puerto serie? De ser asi, como tendria que configurarlo desde java? </p>
<p>Saludos.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7513</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Wed, 04 Mar 2009 21:47:08 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7513</guid>
		<description>Hola Ulises,

esos códigos de EXIT normalmente se dan por problemas con la memoria de tu aplicación. Revisa cuanta memoria flash y ram tienes disponible antes del shutdown. No apagues el módem tampoco a capón, es decir, de forma habitual quitándole la alimentación, apaga el módem con el comando disponible para ello, el AT^SMSO.

La excepción es a nivel de módulo, nada tiene que ver con java, es decir, nada tiene que ver con el watchdog. Puedes configuar con el pin de IGN (no recuerdo si dejándolo a 0 o a 1) para que tras el shutdown siempre se reinicie el módem. Por ejemplo el MTX65 está hecho así. Se garantiza siempre que el equipo va a estar encendido.

Salu2.

Salu2.</description>
		<content:encoded><![CDATA[<p>Hola Ulises,</p>
<p>esos códigos de EXIT normalmente se dan por problemas con la memoria de tu aplicación. Revisa cuanta memoria flash y ram tienes disponible antes del shutdown. No apagues el módem tampoco a capón, es decir, de forma habitual quitándole la alimentación, apaga el módem con el comando disponible para ello, el AT^SMSO.</p>
<p>La excepción es a nivel de módulo, nada tiene que ver con java, es decir, nada tiene que ver con el watchdog. Puedes configuar con el pin de IGN (no recuerdo si dejándolo a 0 o a 1) para que tras el shutdown siempre se reinicie el módem. Por ejemplo el MTX65 está hecho así. Se garantiza siempre que el equipo va a estar encendido.</p>
<p>Salu2.</p>
<p>Salu2.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ulises</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7476</link>
		<dc:creator>Ulises</dc:creator>
		<pubDate>Mon, 02 Mar 2009 15:43:30 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7476</guid>
		<description>Buenas, en primer lugar quiero felicitar a la gente que hace esta pagina por que es excelente!!!
Estoy teniendo problemas en mi aplicacion java, ya que en un determinado momento, aleatoriamente, me lanza el mensaje ^SHUTDOW ^EXIT y no puedo encontrar el problema. Estoy usando un TC65 con la version de fw 3.0.
Quiero saber si hay alguna forma de configurar el comando Autoexec para que el modulo se resetee automaticamente despues que me largue esta excepcion. Probe el ejemplo del Watchdog que publicaste, y en el momento que debe resetear la aplicacion me larga el ^SHUTDOWN y no se resetea.Configure el comando ^SCFG: "Userware/Watchdog","1". Que estoy haciendo mal?  Muchas Gracias.</description>
		<content:encoded><![CDATA[<p>Buenas, en primer lugar quiero felicitar a la gente que hace esta pagina por que es excelente!!!<br />
Estoy teniendo problemas en mi aplicacion java, ya que en un determinado momento, aleatoriamente, me lanza el mensaje ^SHUTDOW ^EXIT y no puedo encontrar el problema. Estoy usando un TC65 con la version de fw 3.0.<br />
Quiero saber si hay alguna forma de configurar el comando Autoexec para que el modulo se resetee automaticamente despues que me largue esta excepcion. Probe el ejemplo del Watchdog que publicaste, y en el momento que debe resetear la aplicacion me larga el ^SHUTDOWN y no se resetea.Configure el comando ^SCFG: &#8220;Userware/Watchdog&#8221;,&#8221;1&#8243;. Que estoy haciendo mal?  Muchas Gracias.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7316</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Thu, 12 Feb 2009 18:45:15 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7316</guid>
		<description>Hola Richi,

no hablo del XT65, hablo del MTX65 que tiene un TC65 en su interior, no un XT65. El TC65 llega hasta la versión 3, el XT65 hasta la 2.

Salu2</description>
		<content:encoded><![CDATA[<p>Hola Richi,</p>
<p>no hablo del XT65, hablo del MTX65 que tiene un TC65 en su interior, no un XT65. El TC65 llega hasta la versión 3, el XT65 hasta la 2.</p>
<p>Salu2</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Richi</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7305</link>
		<dc:creator>Richi</dc:creator>
		<pubDate>Thu, 12 Feb 2009 15:36:46 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7305</guid>
		<description>Hi blogElectronica:

Are you saying that there is firmware release 3 for the XT65 device?  I think there is only release 2 for the XT65 device.

Thanks.</description>
		<content:encoded><![CDATA[<p>Hi blogElectronica:</p>
<p>Are you saying that there is firmware release 3 for the XT65 device?  I think there is only release 2 for the XT65 device.</p>
<p>Thanks.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Richi</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7304</link>
		<dc:creator>Richi</dc:creator>
		<pubDate>Thu, 12 Feb 2009 15:33:52 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7304</guid>
		<description>Hi Oja: 
I have the same problem.  I have 4 XT65 release 1 with the same software, configuration and situation and sametimes one is working fine 20 minutes or 3 hours.  I don´t know why. Sometimes one device is working fine 3 hours and the next time it is working only 20 minutes before it is stopped without warning or error messages.

Are you saying that the problem is resolved with release 3 of firmware?

Thanks. Richi</description>
		<content:encoded><![CDATA[<p>Hi Oja:<br />
I have the same problem.  I have 4 XT65 release 1 with the same software, configuration and situation and sametimes one is working fine 20 minutes or 3 hours.  I don´t know why. Sometimes one device is working fine 3 hours and the next time it is working only 20 minutes before it is stopped without warning or error messages.</p>
<p>Are you saying that the problem is resolved with release 3 of firmware?</p>
<p>Thanks. Richi</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7045</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Sat, 31 Jan 2009 11:47:15 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7045</guid>
		<description>Hi JQ,

You can use the MTX65v3 to solve your problem. MTX65 is always on.

But if you want to use your TC65T, set the modem with:

AT^SCFG="MEShutdown/OnIgnition","off"

and connect pin 20 with pin 12, your TC65T will be always on.

Best regards.</description>
		<content:encoded><![CDATA[<p>Hi JQ,</p>
<p>You can use the MTX65v3 to solve your problem. MTX65 is always on.</p>
<p>But if you want to use your TC65T, set the modem with:</p>
<p>AT^SCFG=&#8221;MEShutdown/OnIgnition&#8221;,&#8221;off&#8221;</p>
<p>and connect pin 20 with pin 12, your TC65T will be always on.</p>
<p>Best regards.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: JQ</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7031</link>
		<dc:creator>JQ</dc:creator>
		<pubDate>Fri, 30 Jan 2009 16:59:37 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7031</guid>
		<description>I hove the same problem with my modems (which must be always on 24h)...
dont no the problem.</description>
		<content:encoded><![CDATA[<p>I hove the same problem with my modems (which must be always on 24h)&#8230;<br />
dont no the problem.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: JQ</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7030</link>
		<dc:creator>JQ</dc:creator>
		<pubDate>Fri, 30 Jan 2009 16:57:28 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-7030</guid>
		<description>hi there,

The activation of the watchdog function (by at^scfg=watchdog,1) presumes always the use of java library watchdog.kick()??? i.e. is always controlled by software????

In case of yes, if my modem TC65T autoshutdown for no reason - with unexpectederror (my modem must be always on) the watchdog doesn't do anything........... bahhhhhhh..........</description>
		<content:encoded><![CDATA[<p>hi there,</p>
<p>The activation of the watchdog function (by at^scfg=watchdog,1) presumes always the use of java library watchdog.kick()??? i.e. is always controlled by software????</p>
<p>In case of yes, if my modem TC65T autoshutdown for no reason - with unexpectederror (my modem must be always on) the watchdog doesn&#8217;t do anything&#8230;&#8230;&#8230;.. bahhhhhhh&#8230;&#8230;&#8230;.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-4590</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Sat, 22 Nov 2008 07:07:17 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-4590</guid>
		<description>Muy buenas Jose A.

la verdad es que no tengo ninguno. A ver si saco un poco de tiempo y pongo alguno dentro de poco. Por ahora sigo funcionando con los AT de toda la vida.

Salu2.</description>
		<content:encoded><![CDATA[<p>Muy buenas Jose A.</p>
<p>la verdad es que no tengo ninguno. A ver si saco un poco de tiempo y pongo alguno dentro de poco. Por ahora sigo funcionando con los AT de toda la vida.</p>
<p>Salu2.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: jose Grande</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-4575</link>
		<dc:creator>jose Grande</dc:creator>
		<pubDate>Fri, 21 Nov 2008 12:12:11 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-4575</guid>
		<description>Hola, no veo ningun post sobre como usar la api de las GPIO que incorpora el nuevo Firmware, y no tengo ni idea de como utilizarla. Agradecería mucho un poco de luz sobre este tema. Muchas gracias..</description>
		<content:encoded><![CDATA[<p>Hola, no veo ningun post sobre como usar la api de las GPIO que incorpora el nuevo Firmware, y no tengo ni idea de como utilizarla. Agradecería mucho un poco de luz sobre este tema. Muchas gracias..</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3662</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Fri, 10 Oct 2008 15:47:41 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3662</guid>
		<description>Hola Jose,

con tanto tiempo ya he visto muchas cosas, pero que el equipo se apague sin enviar ningún URC no lo he visto a menos que se le corte la alimentación de forma fulminante (sino daría un URC undervoltage).

Entiendo que no utilizas un terminal sino un módulo. Yo monitorizaría, si puedes con un osciloscopio, la alimentación de éste último, no vaya a ser que no esté bien dimensionada la fuente y en lugares de baja cobertura, donde el módulo va a consumir más potencia se caiga el sistema. Mira también la alimentación del módulo con AT^SBV (creo que era este) en el momento antes del reinicio misterioso.

Salu2</description>
		<content:encoded><![CDATA[<p>Hola Jose,</p>
<p>con tanto tiempo ya he visto muchas cosas, pero que el equipo se apague sin enviar ningún URC no lo he visto a menos que se le corte la alimentación de forma fulminante (sino daría un URC undervoltage).</p>
<p>Entiendo que no utilizas un terminal sino un módulo. Yo monitorizaría, si puedes con un osciloscopio, la alimentación de éste último, no vaya a ser que no esté bien dimensionada la fuente y en lugares de baja cobertura, donde el módulo va a consumir más potencia se caiga el sistema. Mira también la alimentación del módulo con AT^SBV (creo que era este) en el momento antes del reinicio misterioso.</p>
<p>Salu2</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: JoseEB</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3636</link>
		<dc:creator>JoseEB</dc:creator>
		<pubDate>Thu, 09 Oct 2008 17:06:53 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3636</guid>
		<description>Buenas BlogElectronica!

Queria preguntarte una cosa sobre el tc65. Tengo una aplicacion corriendo sobre él, y a veces y de manera aleatoria aparece el ^sysstart, sin ningun AT+CFUN=1,1 ni nada. Ni siquiera muestra un ^shutdown ni nada. Un absoluto misterio, al menos para mi. 

¿Cuales podrian ser las causas de un apagado de este tipo? llevo un objeto runtime con el que voy comprobando la memoria y se me ha reiniciado a veces con 75kb libres, otras veces con 200kb, con lo que en principio no parece ser ese tema.

A ver si puedes echarme una mano que estoy desesperado jeje.


Jose Escobar</description>
		<content:encoded><![CDATA[<p>Buenas BlogElectronica!</p>
<p>Queria preguntarte una cosa sobre el tc65. Tengo una aplicacion corriendo sobre él, y a veces y de manera aleatoria aparece el ^sysstart, sin ningun AT+CFUN=1,1 ni nada. Ni siquiera muestra un ^shutdown ni nada. Un absoluto misterio, al menos para mi. </p>
<p>¿Cuales podrian ser las causas de un apagado de este tipo? llevo un objeto runtime con el que voy comprobando la memoria y se me ha reiniciado a veces con 75kb libres, otras veces con 200kb, con lo que en principio no parece ser ese tema.</p>
<p>A ver si puedes echarme una mano que estoy desesperado jeje.</p>
<p>Jose Escobar</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Pua</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3247</link>
		<dc:creator>Pua</dc:creator>
		<pubDate>Fri, 19 Sep 2008 09:36:22 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-3247</guid>
		<description>hola,


Parece ser que si será integrada la clase wacthdog en el firmware 2.xxx del XT65/75

Salu2

Pua</description>
		<content:encoded><![CDATA[<p>hola,</p>
<p>Parece ser que si será integrada la clase wacthdog en el firmware 2.xxx del XT65/75</p>
<p>Salu2</p>
<p>Pua</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: blogElectronica</title>
		<link>http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-1869</link>
		<dc:creator>blogElectronica</dc:creator>
		<pubDate>Sun, 13 Apr 2008 11:24:56 +0000</pubDate>
		<guid isPermaLink="false">http://www.blogElectronica.com/watchdog-siemens-tc65-mtx65/#comment-1869</guid>
		<description>Hola Estragón,

no, por ahora no. En cuanto tenga alguna noticia no dudes que lo publicaré en el blog, pero por ahora no sé si se va a incorporar en un futuro o no.

Salu2.</description>
		<content:encoded><![CDATA[<p>Hola Estragón,</p>
<p>no, por ahora no. En cuanto tenga alguna noticia no dudes que lo publicaré en el blog, pero por ahora no sé si se va a incorporar en un futuro o no.</p>
<p>Salu2.</p>
]]></content:encoded>